Proudly serving Lyndhurst and the surrounding area, we’re committed to providing best-in-class solutions for all your home comfort needs.
What Our Customers Are Saying
Emily R. in Lyndhurst, OH
Project: Installed, Repaired or Replaced Plumbing or Fixtures
“Very professional and knowledgeable. The plumber called before he came, was here on time. Did the job he came to do.”
Archana B. in Lyndhurst, OH
Project: Repaired Natural Gas or Propane Furnace / Forced Air Heating System
“Professional and friendly staff. The service was fast and pricing was great.”
Daniel S. in Lyndhurst, OH
Project: Installed, Repaired or Replaced Plumbing or Fixtures
“Excellent communication.”
Frequently Asked Questions from Lyndhurst Customers
Q: If the sewer line leading away from my home is broken or damaged beneath the sidewalk or street, are the repairs my responsibility or the city’s?
In most scenarios, the homeowners are fully responsible for the sewer lines traveling from their home to the sewer main. We’ll be able to have a conversation with you about the best options for repair after conducting a video inspection of the pipes to identify exactly what the problem is and where its at.
Q: Is water filtration only for well water, or are there benefits to filtering city water as well?
Many problems with well water – such as strange tastes, funky odors, and pipe corrosion – can also occur with municipal water. So, yes, water filtration can definitely benefit your Lyndhurst home. Read more about your options here.
Q: What size water heater do I need?
If installing a traditional water heater, the size will depend on how many people are in your home and how much water they use per day. This article includes a table to show you roughly what size hot water tank your family may need.
Recent Jobs and Reviews in Lyndhurst, OH
Lyndhurst, OH at a glance
Kobella Plumbing Heating and Cooling has completed 14 jobs in Lyndhurst, OH between January 2026 and April 2026.
The most recent job was on April 9, 2026.
Job Locations and Reviews
Completed installation of customer-supplied bidet in basement bathroom, connecting water supply line and drain assembly to existing plumbing infrastructure. Repaired continuously running toilet in secondary bathroom by replacing faulty flapper valve and adjusting fill valve mechanism. Inspected kitchen faucet for reported dripping issue, identified worn cartridge as source of leak, and replaced cartridge to restore proper function. Performed additional inspection of kitchen plumbing system for potential leaks, checking under-sink connections, supply lines, and drain assemblies; all connections found secure with no active leaks detected at time of service.
Performed standard flush and fill service on Lochinvar Kobalt tanked water heater located in basement utility room. System was properly drained, sediment removed, and tank refilled to restore optimal operation. Visual inspection confirmed proper venting, secure pipe connections, and overall system integrity.
Completed system installation as a follow-up service, including proper leveling of the outdoor condenser unit against brick exterior. Removed existing humidifier as requested. Performed core drilling through brick wall to accommodate new venting requirements. Verified all components were level and properly secured for optimal system performance.
Diagnosed and serviced an aging furnace system that was non-operational. Inspection revealed issues with the blower motor assembly, identified by significant wear on the motor housing and compromised electrical connections. Replaced the damaged blower motor and restored proper system functionality, allowing for normal heating operation to resume.
Conducted an on-site evaluation for AprilAire DZ installation, taking measurements of the existing HVAC system components and examining the current plumbing configuration. Documented aging copper pipes showing signs of corrosion and assessed available space for new IAQ equipment integration with the existing water heater and ductwork system.
Responded to heating malfunction call and discovered dirty filter causing airflow restriction. Installed new 25 x 2 filter and inspected electrical connections, finding evidence of fluid leakage on terminal connections. Cleaned electrical contacts and restored proper heating operation.
Responded to no-heat call for a 2022 furnace. Diagnosed ignition failure causing loud boom sound. Performed amperage testing with clamp meter showing 0.33A, indicating proper current draw after repair. System restored to normal operation and verified proper function of both furnace and outdoor Trane unit.
Conducted routine plumbing membership visit as requested to inspect outdoor faucet. Examined shower basin showing significant dark staining/mildew accumulation around drain area. Inspected water heater installation with copper supply lines and functioning shut-off valves with red handles; all connections appear properly secured with no visible leaks.
Performed diagnostic on system that was not activating despite temperature differential. Identified faulty pressure switch as the source of the issue. Replaced electrical connection at pressure switch and inspected wiring harness. System now functioning properly with normal operation restored.
Responded to service call for faucet repair. Located and replaced cartridge as per customer's prior arrangement. Inspected surrounding plumbing system including copper piping, pressure gauge, and water heater connections to ensure proper functionality after cartridge replacement.
Returned to complete jackhammer work on concrete slab as previously sold by Chris. Exposed plumbing infrastructure beneath sink fixture to address water damage evident on concrete floor. Removed damaged materials and accessed wall cavity to evaluate plumbing connections and drainage system where moisture intrusion had occurred.
Responded to service call for water leak where customer was unable to locate shutoff valve. Inspection revealed buckling of hardwood flooring in kitchen area due to hidden moisture intrusion. Located and accessed water shutoff valve to stop active leak, then assessed damage to flooring and adjacent cabinetry to determine extent of water damage.
Performed scheduled heating maintenance club visit. Conducted electrical system diagnostics using Fieldpiece SC480 meter to verify system voltage (reading: 5905). All components inspected and operating within normal parameters.
Performed routine 2-year heating maintenance on member's system. Discovered significant ice buildup on evaporator coil indicating possible refrigerant restriction or airflow issues. Used hex key tool to access components for proper inspection and servicing.