HVAC & Plumbing Services in Willoughby, OH

Homeowner adjusting temperature on tankless water heater unit

If your home is uncomfortable, noisy, leaking, or simply not working the way it should, you need a team that can solve the issue fast — and fix it the right way. Kobella Plumbing Heating Cooling helps Willoughby homeowners protect their comfort, reduce utility waste, and avoid repeat repairs.

We provide dependable HVAC and plumbing services in Willoughby and across Lake County, Geauga County, and the Chagrin Valley. Our team has built a reputation for respectful service, straightforward recommendations, and workmanship you can trust.

Explore our most requested services below, or schedule an appointment today.

Expert Plumbing Services in Willoughby

Plumbing problems have a way of turning into expensive damage when they are ignored. Whether you need a targeted repair or a full replacement, our plumbers deliver practical solutions built for long-term reliability.

Kitchen Plumbing

Slow drains, leaking supply lines, broken fixtures, and disposal issues can disrupt your whole routine. Our team handles common kitchen plumbing repairs and upgrades so your sink, faucet, and drains work the way they should.

Sump Pumps

Basements in Northeast Ohio can take on water quickly after heavy rain. A working sump pump helps protect your foundation, storage, and finished basement areas. We provide repairs, replacements, and new installations based on your home’s needs.

Backflow Prevention

Backflow issues can lead to water quality concerns and repeated service calls. Kobella installs and services backflow prevention solutions to help keep water moving in the right direction and protect your plumbing system.

Reliable Heating for Willoughby Homes

Willoughby winters put heating systems to the test. If your home has uneven heat, odd smells, short cycling, or rising utility bills, it is time to have your system checked. Kobella provides heating repairs, replacements, and maintenance to keep your home comfortable through the coldest weeks.

Furnaces

Older furnaces can struggle after sitting idle through warmer months. If your system is blowing cool air, making unusual noises, or failing to start reliably, we can diagnose the issue and recommend the most cost-effective fix.

Heat Pumps

If you want efficient heating with added cooling benefits, heat pumps can be a smart option. Kobella helps Willoughby homeowners understand sizing, efficiency, and installation requirements — and we service existing heat pump systems as well.

Radiant Heating

For homeowners who want consistent comfort without the temperature swings of forced air, radiant heating can be an excellent choice. We provide service and installation guidance so you can decide if radiant heat fits your home and budget.

Willoughby Cooling & Air Conditioning Services

Outdoor air conditioning unit at a home

When summer heat and humidity hit, you need an AC system you can count on. Kobella provides repairs, maintenance, and installation for a wide range of air conditioning systems across Willoughby.

Ductless Air Conditioning

Want room-by-room control without extending ductwork? Ductless mini-splits are a flexible option for additions, older homes, and targeted comfort upgrades.

AC Repair

If your system is not cooling, is freezing over, or is making new noises, do not wait for a full breakdown. Our technicians provide fast, accurate AC repair and clear next steps.

AC Installation

If your system is aging or running inefficiently, replacing it can improve comfort and reduce operating costs. Kobella provides honest recommendations and professional AC installation based on your home’s layout and cooling demands.

Why Choose Kobella in Willoughby?

You deserve more than a quick patch. Kobella is known for professional service and solutions built to last. Homeowners choose us for:

  • Skilled technicians who focus on quality and safety.
  • Clear communication and options you can understand.
  • Transparent pricing with no surprise add-ons.
  • Respectful service that puts your home first.

Partner With Local HVAC & Plumbing Experts Today

If you need plumbing or HVAC service in Willoughby, Kobella is ready to help. Get started with a quote and a plan that fits your home.

Schedule an appointment now.

Community Involvement

It’s always a pleasure working with the Lake County Department of Utilities on Willoughby water line jobs. Kobella Plumbing Heating Cooling is a registered sewer and water contractor with the Lake County Department of Utilities, which allows us to install and repair water lines in Willoughby.

What Our Customers Are Saying

Janice R. in Willoughby, OH

Project: Repaired and replaced plumbing and fixtures

“I had a mystery water stain on the kitchen ceiling. Kobella responded quickly and Tim took his time to figure out what my problem was. As it turned out, not a plumbing problem at all. I will call Kobella again for anything related to plumbing and heating.”

Shane M. in Willoughby, OH

Project: Repaired and replaced plumbing and fixtures

“Extremely knowledgeable and professional. I would recommend them in an instant to anyone.”

Homeowner in Willoughby, OH

Project: Installed a sump pump

“Thank you Mike and Anthony for the recent install of our backup system for our existing sump pump for our house. You understood what we needed, provided a great product, shared your expertise and knowledge with the system and were respectful, considerate and professional from the very minute you met with us to the completion of work. We can say that we are even more delighted to have a reputable and honest organization that we can trust with our future needs. Keep up the great work. There are more people out there that are looking for a plumbing company like yours!”

Rebecca C. in Willoughby, OH

Project: Repaired and replaced plumbing and fixtures

“Replaced toilet, added a vent under the sink and found major septic pipe issues. Professional, up front with pricing and even understanding of our very friendly dogs.”

Frequently Asked Questions from Willoughby Customers

If installing a traditional water heater, the size depends on household size and daily hot water demand. This article includes a table to help you estimate sizing: water heater sizing guide.

Use this checklist to reduce the risk of frozen pipes and unexpected breakdowns: winter prep checklist. If you want help identifying vulnerable pipes or insulation gaps, call our team.

This can happen for multiple reasons, but a common cause is a well pump issue. Start here: well pump troubleshooting.

Featured Services & Coupons

Recent Jobs and Reviews in Willoughby, OH

Job Locations and Reviews

Responded to service call for leaking hot water tank in 17-year-old residential property. Conducted visual inspection of water heater unit and surrounding plumbing connections to identify source of leak. Documented existing conditions with photographs for warranty verification purposes, as unit age falls within potential manufacturer warranty coverage period. Assessed leak severity and provided homeowner with recommendations regarding warranty claim process and potential replacement options given the age of the equipment and home.
Responded to service call for leaking hot water tank in 17-year-old residential property. Conducted visual inspection of water heater unit and surrounding plumbing connections to identify source of leak. Documented existing conditions with photographs for warranty verification purposes, as unit age falls within potential manufacturer warranty coverage period. Assessed leak severity and provided homeowner with recommendations regarding warranty claim process and potential replacement options given the age of the equipment and home.
Homer J.
Homer J. Checked in
Responded to service call for leaking hot water tank in 17-year-old residential property. Conducted visual inspection of water heater unit and surrounding plumbing connections to identify source of leak. Documented existing conditions with photographs for warranty verification purposes, as unit age falls within potential manufacturer warranty coverage period. Assessed leak severity and provided homeowner with recommendations regarding warranty claim process and potential replacement options given the age of the equipment and home.
Willoughby, OH 44094
Responded to emergency call for ceiling leak originating from heating system piping. Upon arrival, found active water intrusion with extensive ceiling damage, including compromised drywall, significant water staining, and exposed structural members. Inspection revealed severely deteriorated wooden joists and beams with dark staining indicating prolonged moisture exposure and potential microbial growth. Located source of leak at corroded heating system pipe running through ceiling cavity.

Implemented immediate damage control measures by installing protective plastic sheeting to contain water flow and prevent further interior damage. Documented extensive deterioration of ceiling structure and heating pipe condition through photographic evidence. Advised customer of emergency nature of repairs needed and provided contact information for follow-up restoration work.
Responded to emergency call for ceiling leak originating from heating system piping. Upon arrival, found active water intrusion with extensive ceiling damage, including compromised drywall, significant water staining, and exposed structural members. Inspection revealed severely deteriorated wooden joists and beams with dark staining indicating prolonged moisture exposure and potential microbial growth. Located source of leak at corroded heating system pipe running through ceiling cavity.

Implemented immediate damage control measures by installing protective plastic sheeting to contain water flow and prevent further interior damage. Documented extensive deterioration of ceiling structure and heating pipe condition through photographic evidence. Advised customer of emergency nature of repairs needed and provided contact information for follow-up restoration work.
Matt H.
Matt H. Checked in
Responded to emergency call for ceiling leak originating from heating system piping. Upon arrival, found active water intrusion with extensive ceiling damage, including compromised drywall, significant water staining, and exposed structural members. Inspection revealed severely deteriorated wooden joists and beams with dark staining indicating prolonged moisture exposure and potential microbial growth. Located source of leak at corroded heating system pipe running through ceiling cavity. Implemented immediate damage control measures by installing protective plastic sheeting to contain water flow and prevent further interior damage. Documented extensive deterioration of ceiling structure and heating pipe condition through photographic evidence. Advised customer of emergency nature of repairs needed and provided contact information for follow-up restoration work.
Willoughby, OH 44094
Performed routine cooling maintenance member visit on Trane air conditioning unit (Model A4AC3030A1000AA, Serial 20392NP5BF). Conducted system diagnostics using digital multimeter, recording temperature reading of 497°F at measured component. Completed standard inspection of 3-ton AC unit manufactured September 2020, verified unit specifications including 208/230V single-phase operation at 16.0 amps with R-410A refrigerant charge of 25 oz.
Performed routine cooling maintenance member visit on Trane air conditioning unit (Model A4AC3030A1000AA, Serial 20392NP5BF). Conducted system diagnostics using digital multimeter, recording temperature reading of 497°F at measured component. Completed standard inspection of 3-ton AC unit manufactured September 2020, verified unit specifications including 208/230V single-phase operation at 16.0 amps with R-410A refrigerant charge of 25 oz.
Jeff M.
Jeff M. Checked in
Performed routine cooling maintenance member visit on Trane air conditioning unit (Model A4AC3030A1000AA, Serial 20392NP5BF). Conducted system diagnostics using digital multimeter, recording temperature reading of 497°F at measured component. Completed standard inspection of 3-ton AC unit manufactured September 2020, verified unit specifications including 208/230V single-phase operation at 16.0 amps with R-410A refrigerant charge of 25 oz.
Willoughby, OH 44094
Willoughby, OH - Performed warranty service to reseat air conditioning unit that had settled due to soil subsidence following excavation work. Unit was releveled and repositioned on stable foundation to ensure proper operation and prevent future mechanical stress on refrigerant lines and electrical connections. Documentation photos captured condition of work area showing evidence of settling and completed repositioning of equipment.
Jeff M.
Jeff M. Checked in
Performed warranty service to reseat air conditioning unit that had settled due to soil subsidence following excavation work. Unit was releveled and repositioned on stable foundation to ensure proper operation and prevent future mechanical stress on refrigerant lines and electrical connections. Documentation photos captured condition of work area showing evidence of settling and completed repositioning of equipment.
Willoughby, OH 44094
Completed full HVAC system installation including an 80,000 BTU furnace and 3-ton 15 SEER air conditioning unit with weathered top cabinet. Sealed return air panning throughout the system to eliminate air leakage and improve efficiency. Installed Aprilaire whole-home humidifier for enhanced indoor air quality and comfort control. Repaired and sealed 6-inch ductwork take-off connection that was previously compromised. Replaced fuses in electrical disconnect as part of system commissioning and safety verification. Installed water heater concurrent with HVAC equipment replacement. All equipment tested, leveled, and verified operational per manufacturer specifications.
Completed full HVAC system installation including an 80,000 BTU furnace and 3-ton 15 SEER air conditioning unit with weathered top cabinet. Sealed return air panning throughout the system to eliminate air leakage and improve efficiency. Installed Aprilaire whole-home humidifier for enhanced indoor air quality and comfort control. Repaired and sealed 6-inch ductwork take-off connection that was previously compromised. Replaced fuses in electrical disconnect as part of system commissioning and safety verification. Installed water heater concurrent with HVAC equipment replacement. All equipment tested, leveled, and verified operational per manufacturer specifications.
Joel R.
Joel R. Checked in
Completed full HVAC system installation including an 80,000 BTU furnace and 3-ton 15 SEER air conditioning unit with weathered top cabinet. Sealed return air panning throughout the system to eliminate air leakage and improve efficiency. Installed Aprilaire whole-home humidifier for enhanced indoor air quality and comfort control. Repaired and sealed 6-inch ductwork take-off connection that was previously compromised. Replaced fuses in electrical disconnect as part of system commissioning and safety verification. Installed water heater concurrent with HVAC equipment replacement. All equipment tested, leveled, and verified operational per manufacturer specifications.
Willoughby, OH 44094
Installed 50-gallon A.O. Smith standard vent gas water heater with drip pan capped per customer request to eliminate above-ground tripping hazard. Unit installed with proper gas connections, verified burner ignition and flame pattern, and confirmed all safety labels and specifications are visible on exterior of tank.
Installed 50-gallon A.O. Smith standard vent gas water heater with drip pan capped per customer request to eliminate above-ground tripping hazard. Unit installed with proper gas connections, verified burner ignition and flame pattern, and confirmed all safety labels and specifications are visible on exterior of tank.
Sam F.
Sam F. Checked in
Installed 50-gallon A.O. Smith standard vent gas water heater with drip pan capped per customer request to eliminate above-ground tripping hazard. Unit installed with proper gas connections, verified burner ignition and flame pattern, and confirmed all safety labels and specifications are visible on exterior of tank.
Willoughby, OH 44094
Completed return visit for cracked clay pipe replacement with PVC piping. Installed new toilet in bathroom with mosaic tile walls and performed leak repair behind dryer unit. All plumbing fixtures tested and verified operational upon completion.
Completed return visit for cracked clay pipe replacement with PVC piping. Installed new toilet in bathroom with mosaic tile walls and performed leak repair behind dryer unit. All plumbing fixtures tested and verified operational upon completion.
Sam F.
Sam F. Checked in
Completed return visit for cracked clay pipe replacement with PVC piping. Installed new toilet in bathroom with mosaic tile walls and performed leak repair behind dryer unit. All plumbing fixtures tested and verified operational upon completion.
Willoughby, OH 44094
Completed HVAC estimate for air conditioning system replacement on property with 12-14 year old existing AC unit that has experienced operational issues. Customer elected to proceed with AC replacement at this time and defer furnace replacement for approximately one year, despite existing furnace also being 12-14 years old. Inspected current system configuration including furnace control board, ductwork, and equipment layout in basement mechanical room. Documented existing equipment conditions and provided replacement options for relocating outdoor condensing unit to preferred location. Photographed furnace circuit board showing control wiring, relays, and flame sensor components, as well as overall mechanical room setup with gas furnace, water heater, and duct distribution system.
Completed HVAC estimate for air conditioning system replacement on property with 12-14 year old existing AC unit that has experienced operational issues. Customer elected to proceed with AC replacement at this time and defer furnace replacement for approximately one year, despite existing furnace also being 12-14 years old. Inspected current system configuration including furnace control board, ductwork, and equipment layout in basement mechanical room. Documented existing equipment conditions and provided replacement options for relocating outdoor condensing unit to preferred location. Photographed furnace circuit board showing control wiring, relays, and flame sensor components, as well as overall mechanical room setup with gas furnace, water heater, and duct distribution system.
Justin W.
Justin W. Checked in
Completed HVAC estimate for air conditioning system replacement on property with 12-14 year old existing AC unit that has experienced operational issues. Customer elected to proceed with AC replacement at this time and defer furnace replacement for approximately one year, despite existing furnace also being 12-14 years old. Inspected current system configuration including furnace control board, ductwork, and equipment layout in basement mechanical room. Documented existing equipment conditions and provided replacement options for relocating outdoor condensing unit to preferred location. Photographed furnace circuit board showing control wiring, relays, and flame sensor components, as well as overall mechanical room setup with gas furnace, water heater, and duct distribution system.
Willoughby, OH 44094
Completed routine HVAC club maintenance visit on both furnace and air conditioning system. Inspected dual-run capacitor rated at 45/5 µF 440V, confirmed proper operation and no signs of bulging or deterioration, and verified electrical connections secure with proper wire terminations. Measured system amperage readings using calibrated multimeter, recording 23.53 amps with zero inrush current detected, indicating normal compressor operation within manufacturer specifications.
Completed routine HVAC club maintenance visit on both furnace and air conditioning system. Inspected dual-run capacitor rated at 45/5 µF 440V, confirmed proper operation and no signs of bulging or deterioration, and verified electrical connections secure with proper wire terminations. Measured system amperage readings using calibrated multimeter, recording 23.53 amps with zero inrush current detected, indicating normal compressor operation within manufacturer specifications.
Sam K.
Sam K. Checked in
Completed routine HVAC club maintenance visit on both furnace and air conditioning system. Inspected dual-run capacitor rated at 45/5 µF 440V, confirmed proper operation and no signs of bulging or deterioration, and verified electrical connections secure with proper wire terminations. Measured system amperage readings using calibrated multimeter, recording 23.53 amps with zero inrush current detected, indicating normal compressor operation within manufacturer specifications.
Willoughby, OH 44094
Willoughby, OH - Responded to outdoor hose bib leak at rear of residence. Upon inspection, found water seepage from spigot body despite shutoff valve being fully closed. Replaced faulty hose bib with new frost-free unit, ensuring proper seal against vinyl siding and verified complete water shutoff functionality.
Sam F.
Sam F. Checked in
Responded to outdoor hose bib leak at rear of residence. Upon inspection, found water seepage from spigot body despite shutoff valve being fully closed. Replaced faulty hose bib with new frost-free unit, ensuring proper seal against vinyl siding and verified complete water shutoff functionality.
Willoughby, OH 44094
Completed heating maintenance club visit on air handler system. Performed electrical diagnostics using clamp meter, recording amperage draw of 0.28 amps on system components. Measured static pressure differential across system using dual port manometer, with readings of 186 and 180, indicating proper airflow through the unit. All measurements within manufacturer specifications, confirming system operating efficiently for the heating season.
Completed heating maintenance club visit on air handler system. Performed electrical diagnostics using clamp meter, recording amperage draw of 0.28 amps on system components. Measured static pressure differential across system using dual port manometer, with readings of 186 and 180, indicating proper airflow through the unit. All measurements within manufacturer specifications, confirming system operating efficiently for the heating season.
Jeff M.
Jeff M. Checked in
Completed heating maintenance club visit on air handler system. Performed electrical diagnostics using clamp meter, recording amperage draw of 0.28 amps on system components. Measured static pressure differential across system using dual port manometer, with readings of 186 and 180, indicating proper airflow through the unit. All measurements within manufacturer specifications, confirming system operating efficiently for the heating season.
Willoughby, OH 44094
Replaced two bathroom faucets and connected new flexible braided supply lines to existing shut-off valves. Verified proper drainage through P-trap assembly and tested for leaks at all connection points.
Replaced two bathroom faucets and connected new flexible braided supply lines to existing shut-off valves. Verified proper drainage through P-trap assembly and tested for leaks at all connection points.
Homer J.
Homer J. Checked in
Replaced two bathroom faucets and connected new flexible braided supply lines to existing shut-off valves. Verified proper drainage through P-trap assembly and tested for leaks at all connection points.
Willoughby, OH 44094
Responded to gas odor complaint reported in basement and upper levels of residence. Performed comprehensive gas pressure test on system using calibrated pressure gauge to verify system integrity and identify potential leak sources. Conducted diagnostic testing on heating equipment with combustion analysis, confirming proper burner operation and flame characteristics while investigating reported gas smell throughout the property.
Responded to gas odor complaint reported in basement and upper levels of residence. Performed comprehensive gas pressure test on system using calibrated pressure gauge to verify system integrity and identify potential leak sources. Conducted diagnostic testing on heating equipment with combustion analysis, confirming proper burner operation and flame characteristics while investigating reported gas smell throughout the property.
Chris M.
Chris M. Checked in
Responded to gas odor complaint reported in basement and upper levels of residence. Performed comprehensive gas pressure test on system using calibrated pressure gauge to verify system integrity and identify potential leak sources. Conducted diagnostic testing on heating equipment with combustion analysis, confirming proper burner operation and flame characteristics while investigating reported gas smell throughout the property.
Willoughby, OH 44094
Returned to complete installation of 40-gallon water heater that was previously sold. Removed deteriorated PVC drain line showing significant mineral buildup and sediment accumulation on interior walls. Replaced compromised piping with new PVC components and verified proper combustion operation, with burner assembly displaying clean blue flame characteristics and appropriate heat distribution throughout the unit.
Returned to complete installation of 40-gallon water heater that was previously sold. Removed deteriorated PVC drain line showing significant mineral buildup and sediment accumulation on interior walls. Replaced compromised piping with new PVC components and verified proper combustion operation, with burner assembly displaying clean blue flame characteristics and appropriate heat distribution throughout the unit.
Chris M.
Chris M. Checked in
Returned to complete installation of 40-gallon water heater that was previously sold. Removed deteriorated PVC drain line showing significant mineral buildup and sediment accumulation on interior walls. Replaced compromised piping with new PVC components and verified proper combustion operation, with burner assembly displaying clean blue flame characteristics and appropriate heat distribution throughout the unit.
Willoughby, OH 44094
Completed routine plumbing membership inspection of residential property, examining both crawlspace plumbing infrastructure and bathroom fixtures. Inspected exposed piping in basement area, including gray supply lines secured with metal hangers, flexible conduit connections, and verified structural mounting points beneath floor joists. Evaluated modern bathroom shower enclosure featuring frameless glass door system, marble-effect tile surround, recessed storage niche, and wall-mounted handheld shower fixture with black mounting hardware, confirming all plumbing fixtures and connections were functioning properly with no visible leaks or immediate concerns noted.
Completed routine plumbing membership inspection of residential property, examining both crawlspace plumbing infrastructure and bathroom fixtures. Inspected exposed piping in basement area, including gray supply lines secured with metal hangers, flexible conduit connections, and verified structural mounting points beneath floor joists. Evaluated modern bathroom shower enclosure featuring frameless glass door system, marble-effect tile surround, recessed storage niche, and wall-mounted handheld shower fixture with black mounting hardware, confirming all plumbing fixtures and connections were functioning properly with no visible leaks or immediate concerns noted.
Sam F.
Sam F. Checked in
Completed routine plumbing membership inspection of residential property, examining both crawlspace plumbing infrastructure and bathroom fixtures. Inspected exposed piping in basement area, including gray supply lines secured with metal hangers, flexible conduit connections, and verified structural mounting points beneath floor joists. Evaluated modern bathroom shower enclosure featuring frameless glass door system, marble-effect tile surround, recessed storage niche, and wall-mounted handheld shower fixture with black mounting hardware, confirming all plumbing fixtures and connections were functioning properly with no visible leaks or immediate concerns noted.
Willoughby, OH 44094
Completed heating maintenance club visit on air handler system. Performed thorough inspection using borescope camera to examine internal components and ductwork connections, verifying proper assembly and identifying any potential issues within confined spaces. System operating within normal parameters upon completion of maintenance procedures.
Completed heating maintenance club visit on air handler system. Performed thorough inspection using borescope camera to examine internal components and ductwork connections, verifying proper assembly and identifying any potential issues within confined spaces. System operating within normal parameters upon completion of maintenance procedures.
Matt H.
Matt H. Checked in
Completed heating maintenance club visit on air handler system. Performed thorough inspection using borescope camera to examine internal components and ductwork connections, verifying proper assembly and identifying any potential issues within confined spaces. System operating within normal parameters upon completion of maintenance procedures.
Willoughby, OH 44094
Conducted comprehensive HVAC system evaluation for residential property with 38-year-old gas furnace and 20-year-old air conditioning system experiencing diminished operational efficiency. Assessed existing equipment, ductwork penetrations through basement insulation, and electrical service capacity at main distribution panel to determine replacement specifications and system compatibility requirements for new high-efficiency heating and cooling installation.
Conducted comprehensive HVAC system evaluation for residential property with 38-year-old gas furnace and 20-year-old air conditioning system experiencing diminished operational efficiency. Assessed existing equipment, ductwork penetrations through basement insulation, and electrical service capacity at main distribution panel to determine replacement specifications and system compatibility requirements for new high-efficiency heating and cooling installation.
Greg H.
Greg H. Checked in
Conducted comprehensive HVAC system evaluation for residential property with 38-year-old gas furnace and 20-year-old air conditioning system experiencing diminished operational efficiency. Assessed existing equipment, ductwork penetrations through basement insulation, and electrical service capacity at main distribution panel to determine replacement specifications and system compatibility requirements for new high-efficiency heating and cooling installation.
Willoughby, OH 44094
Performed comprehensive assessment of 17-year-old residential water heater unit originally installed in 2009. Documentation revealed significant age-related deterioration with visible corrosion and mineral deposit accumulation at pipe penetration points, indicating potential leak concerns. Provided detailed estimate for complete water heater replacement, including photographic documentation of existing unit condition and corrosion damage to support recommendation for immediate replacement due to equipment exceeding typical service life expectancy.
Performed comprehensive assessment of 17-year-old residential water heater unit originally installed in 2009. Documentation revealed significant age-related deterioration with visible corrosion and mineral deposit accumulation at pipe penetration points, indicating potential leak concerns. Provided detailed estimate for complete water heater replacement, including photographic documentation of existing unit condition and corrosion damage to support recommendation for immediate replacement due to equipment exceeding typical service life expectancy.
Chris M.
Chris M. Checked in
Performed comprehensive assessment of 17-year-old residential water heater unit originally installed in 2009. Documentation revealed significant age-related deterioration with visible corrosion and mineral deposit accumulation at pipe penetration points, indicating potential leak concerns. Provided detailed estimate for complete water heater replacement, including photographic documentation of existing unit condition and corrosion damage to support recommendation for immediate replacement due to equipment exceeding typical service life expectancy.
Willoughby, OH 44094
Completed cooling maintenance club visit at residential property. Performed comprehensive inspection of HVAC system including indoor air handler unit and outdoor condensing unit. Inspected furnace/air handler assembly, verified proper operation of hot water heater connections, and examined PVC condensate drain lines with visible shutoff valves. Conducted detailed examination of outdoor heat pump unit with housing removed, inspecting compressor assembly, refrigerant line connections, and copper tubing for signs of wear or damage. Noted moisture accumulation and minor discoloration on condenser base pan beneath compressor. Verified electrical connections and wiring integrity throughout system. All components operating within normal parameters upon completion of maintenance inspection.
Completed cooling maintenance club visit at residential property. Performed comprehensive inspection of HVAC system including indoor air handler unit and outdoor condensing unit. Inspected furnace/air handler assembly, verified proper operation of hot water heater connections, and examined PVC condensate drain lines with visible shutoff valves. Conducted detailed examination of outdoor heat pump unit with housing removed, inspecting compressor assembly, refrigerant line connections, and copper tubing for signs of wear or damage. Noted moisture accumulation and minor discoloration on condenser base pan beneath compressor. Verified electrical connections and wiring integrity throughout system. All components operating within normal parameters upon completion of maintenance inspection.
Ozzie A.
Ozzie A. Checked in
Completed cooling maintenance club visit at residential property. Performed comprehensive inspection of HVAC system including indoor air handler unit and outdoor condensing unit. Inspected furnace/air handler assembly, verified proper operation of hot water heater connections, and examined PVC condensate drain lines with visible shutoff valves. Conducted detailed examination of outdoor heat pump unit with housing removed, inspecting compressor assembly, refrigerant line connections, and copper tubing for signs of wear or damage. Noted moisture accumulation and minor discoloration on condenser base pan beneath compressor. Verified electrical connections and wiring integrity throughout system. All components operating within normal parameters upon completion of maintenance inspection.
Willoughby, OH 44094
Completed sump pump installation in basement crawl space with concrete floor. Cut 18-24 inch diameter sump pit into existing concrete foundation, installed submersible sump pump unit, and ran white PVC discharge piping vertically through wood-framed wall opening to exterior drainage point. Secured discharge pipe with proper mounting and labeled system per code requirements. Tested pump operation and verified proper water level activation and discharge flow.
Completed sump pump installation in basement crawl space with concrete floor. Cut 18-24 inch diameter sump pit into existing concrete foundation, installed submersible sump pump unit, and ran white PVC discharge piping vertically through wood-framed wall opening to exterior drainage point. Secured discharge pipe with proper mounting and labeled system per code requirements. Tested pump operation and verified proper water level activation and discharge flow.
Chris M.
Chris M. Checked in
Completed sump pump installation in basement crawl space with concrete floor. Cut 18-24 inch diameter sump pit into existing concrete foundation, installed submersible sump pump unit, and ran white PVC discharge piping vertically through wood-framed wall opening to exterior drainage point. Secured discharge pipe with proper mounting and labeled system per code requirements. Tested pump operation and verified proper water level activation and discharge flow.
Willoughby, OH 44094
Start Saving Today With

Membership Perks

Start Saving Today With

Membership Perks

What To Expect

Discover The Kobella Difference

Integrity

We provide unmatched repair, replacement, and maintenance services using only the highest quality parts and equipment.

Responsive

When you call us from 8 a.m. to 8 p.m., a technician will arrive that same day to provide the needed services.

Professional

Our knowledgeable technicians do jobs quickly without compromising our commitment to excellence.

Satisfaction Guaranteed

Our team is dedicated to ensuring your 100% satisfaction with every service we perform.

Trusted & Recommended

Our experts have the expertise, training, and extensive industry experience to deliver the highest quality services.

Upfront Pricing

No surprise or hidden fees when you get your invoice. We’re upfront and transparent about pricing from start to finish.

Integrity

We provide unmatched repair, replacement, and maintenance services using only the highest quality parts and equipment.

Responsive

When you call us from 8 a.m. to 8 p.m., a technician will arrive that same day to provide the needed services.

Professional

Our knowledgeable technicians do jobs quickly without compromising our commitment to excellence.

Satisfaction Guaranteed

Our team is dedicated to ensuring your 100% satisfaction with every service we perform.

Trusted & Recommended

Our experts have the expertise, training, and extensive industry experience to deliver the highest quality services.

Upfront Pricing

No surprise or hidden fees when you get your invoice. We’re upfront and transparent about pricing from start to finish.

Review Image
Our Reviews

See What Your Neighbors Are Saying

Had a new combi unit installed to replace an aging boiler and water heater. Couldn’t be happier with the install team! Very professional, knowledgeable, and passionate about their work. They paid attention to the details and executed very well. Extremely happy with the install. Looking forward…

Seth G.

Seth G.

Had a wonderful experience with Kobella. The appointment was set in a very timely fashion. The service technician, Bruno, was professional and courteous. He explained the problem, the different remedies and performed the work quickly and expertly. He cleaned the work area thoroughly and made sure…

Loretta R.

Loretta R.

Our go to call for anything related to plumbing, heating, or cooling. Always available quickly, call ahead prior to arrival and show up on team. Every team member is professional and displays Significant professional knowledge. Have recommended their service to others and feedback has been the…

Mathew R.

Mathew R.

I’m so happy with my new air duct installation! Jon, Greg and the crew were an absolute pleasure to work with from start to finish. Very knowledgeable, hardworking and trustworthy guys who went above and beyond. Super impressed!! Highly recommend Kobella 10/10!!

Carla M.

Carla M.

Kobella did a great job moving my sump drain, replacing the sump pump, and adding a secondary pump with battery backup. They were able to do all of the work the same day as the site survey, and their staff was very friendly and professional. I…

John G.