Heating, Cooling & Plumbing Services in Painesville, OH

AC unit in residential backyard against wood fence

Painesville homes deal with a little bit of everything. Older neighborhoods near Mentor Avenue and Main Street still have aging furnaces, original plumbing lines, and boiler systems that have been running for decades, while newer homes closer to Fairgrounds Road and Route 84 put heavier demand on modern heating and cooling equipment. Between lake effect winters, humid summers, and the mix of older and newer housing throughout the city, Kobella Heating & Cooling stays busy helping Painesville homeowners keep their systems running reliably.

From neighborhoods near Lake Erie College to homes closer to Riverside Drive and the Grand River area, our technicians work throughout Painesville every week. If your furnace, air conditioner, water heater, or plumbing system has started giving you trouble, call (440) 363-6803 or contact Kobella Heating & Cooling online to schedule service in Painesville.

Working in Homes Across Painesville

Painesville has one of the older housing stocks in this part of Lake County, and you can feel that difference from one neighborhood to the next. Around Liberty Street and the downtown area, we regularly work in homes where the original ductwork, drain lines, and heating systems are still in place. Further east near Route 20 and newer residential developments, homeowners often deal with larger layouts, finished basements, and multi-level comfort issues.

Our technicians spend a lot of time helping homeowners solve problems that build slowly over time. One house may struggle with poor airflow upstairs every summer. Another may have a boiler system that has been repaired repeatedly over the years. We also see sump pump concerns after heavy rain moves through the Grand River basin, especially in lower-lying parts of the city.

Cooling & Air Conditioning in Painesville, OH

By the middle of July, some homes near the Grand River and Veterans Park start feeling damp before noon, even with the AC running constantly. We see it often in older houses where airflow was never designed to handle today’s humidity levels or expanded living spaces. Kobella Heating & Cooling provides:

  • AC Repair
  • AC Installation
  • AC Maintenance
  • Ductless Air Conditioning
  • Ductless AC Installation
  • Ductless AC Repair
  • Ductless AC Maintenance
  • Heat Pumps

Finished attics, enclosed porches, and basement remodels have changed the way plenty of Painesville homes heat and cool over the years. In neighborhoods near Mentor Avenue and Painesville Township, we often find the equipment itself is still usable, but the airflow was never adjusted to match how the home evolved.

Plumbing & Water Heater Repair in Painesville, OH

Some plumbing calls in Painesville start with a slow drain or weak water pressure and turn into bigger discoveries once we get underneath the house. Around downtown and older streets near Liberty Street, it is still common to find aging galvanized piping, worn shutoff valves, and sewer connections that have been there for decades. Our plumbing services include:

  • Plumbing Repair
  • Bathroom Plumbing
  • Kitchen Plumbing
  • Water Heaters
  • Water Treatment
  • Sewer & Drain
  • Sump Pumps
  • Gas Lines
  • Water Lines
  • Water Line Repair
  • Well Pumps
  • Backflow Prevention

Older neighborhoods with mature trees near Jackson Street and the Grand River area also tend to see more sewer line intrusion and drainage backups over time. After heavy storms move through Lake County, sump pump failures become a bigger concern in lower-lying parts of the city.

Hard water buildup throughout Lake County can also shorten the lifespan of water heaters and plumbing fixtures over time. If your hot water supply has become inconsistent or your water pressure has dropped, mineral buildup inside the system may be part of the issue.

Heating Repair & Furnace Replacement in Painesville, OH

When lake effect weather settles into Painesville for a few days straight, you start noticing which heating systems are barely hanging on. Homes closer to the lakefront deal with stronger wind exposure, while older houses near Main Street and the downtown area often struggle with airflow problems that leave certain rooms colder than the rest of the house. Heating services available throughout Painesville include:

  • Heating Repair
  • Heating Installation
  • Heating Maintenance
  • Furnaces
  • Boilers
  • Heat Pumps
  • Heat Pump Repair
  • Heat Pump Replacement
  • Heat Pump Installation
  • Heat Pump Maintenance
  • Radiant Heating

We regularly walk into homes near Main Street and Jackson Street where the thermostat says one thing while the back bedrooms feel completely different. Quite a few times, the furnace is not the actual problem. Restricted airflow, aging ductwork, or older blower components are usually what is driving the uneven heating.

Boilers and radiant heating systems are also still common throughout Painesville. Kobella continues servicing systems that many companies no longer spend time repairing properly.

Indoor Air Quality Solutions for Painesville Homes

Some homes in Painesville never seem to feel quite right, even when the thermostat says the temperature should be comfortable. Houses closer to the Grand River often hold onto humidity during summer, while older homes throughout the city can start feeling dry and stale once heating season begins. Kobella Heating & Cooling installs and services:

  • Humidifiers & Dehumidifiers
  • Air Scrubbers & Purifiers

Homes near the Grand River and lower-lying areas often deal with excess moisture during summer, while older homes throughout the city can feel extremely dry once heating season begins. Better humidity control and air filtration can make a noticeable difference in how the home feels day to day.

Why Painesville Homeowners Continue Calling Kobella

Most people calling us in Painesville are already frustrated before we even arrive. The furnace stopped overnight. A drain backed up before work. The basement started taking on water during a storm moving through Lake County. They are not looking for a sales pitch. They want somebody who can figure out the problem, explain what is happening in plain language, and get things working again.

That approach matters in neighborhoods around Riverside High School, Fairgrounds Road, and the older streets near downtown where systems have usually been repaired and modified more than once over the years. Our technicians take time to inspect the full situation, walk homeowners through the options, and recommend repairs that actually make sense for the condition of the house.

What Painesville Area Customers Are Saying

Homer provided excellent service. He explained everything that was going on with my frozen water pipes and provided step-by-step details on what he was doing to resolve the issue.

Brandon C. – Rated 5/5 Stars

Derek is a knowledgeable professional who resolved a difficult plumbing issue. He arrived earlier than expected, stayed late until all repairs were completed, and left the work area in good order.

Betsy P. – Rated 5/5 Stars

Chris came out when I was having major drainage issues in my yard. He was polite, knowledgeable, and explained everything clearly while giving us multiple solutions.

Jeff M. – Rated 5/5 Stars

Schedule Service With a Team That Knows Painesville Homes

Whether you are dealing with a furnace that struggles during lake effect cold snaps, a plumbing issue in an older home near downtown, or an AC system that cannot keep up with summer humidity, Kobella Heating & Cooling is ready to help.

Our technicians already spend their days working in homes throughout Painesville, so they understand the layouts, aging systems, and seasonal problems that tend to show up across this part of Lake County.

you can schedule an appointment with our online tool. Let’s see what we can do for you.

Recent Jobs and Reviews in Painesville, OH

Painesville, OH at a glance

Kobella Plumbing Heating and Cooling has completed 20 jobs in Painesville, OH in October 2026.

The most recent job was on October 28, 2026.

Kobella Plumbing Heating and Cooling has completed 592 jobs in Painesville, OH in the last 12 months.

Job Locations and Reviews

Performed scheduled club maintenance visit on the outdoor condenser unit, including inspection of the louvered protective grille and condenser coil surface. Verified electrical operation using a true RMS clamp meter to measure amperage draw, and noted surrounding debris and leaf buildup around the unit that may restrict airflow.
Performed scheduled club maintenance visit on the outdoor condenser unit, including inspection of the louvered protective grille and condenser coil surface. Verified electrical operation using a true RMS clamp meter to measure amperage draw, and noted surrounding debris and leaf buildup around the unit that may restrict airflow.
Justin T.
Justin T. Checked in
Performed scheduled club maintenance visit on the outdoor condenser unit, including inspection of the louvered protective grille and condenser coil surface. Verified electrical operation using a true RMS clamp meter to measure amperage draw, and noted surrounding debris and leaf buildup around the unit that may restrict airflow.
Painesville, OH 44077
Verified incoming line voltage at the utility outlet (125.2 V) following the utility's electrical service change and confirmed the 24V control transformer was buzzing. Replaced the failed transformer with a new unit under warranty, documenting the repair on the service record tag.
Verified incoming line voltage at the utility outlet (125.2 V) following the utility's electrical service change and confirmed the 24V control transformer was buzzing. Replaced the failed transformer with a new unit under warranty, documenting the repair on the service record tag.
Bruno D.
Bruno D. Checked in
Verified incoming line voltage at the utility outlet (125.2 V) following the utility's electrical service change and confirmed the 24V control transformer was buzzing. Replaced the failed transformer with a new unit under warranty, documenting the repair on the service record tag.
Painesville, OH 44077
Performed annual heating maintenance on the gas furnace, including inspection of the blower compartment, wiring, and condensate drain piping. Verified static pressure with a digital manometer and conducted a combustion analysis, recording 9.3% Oâ‚‚ and 6 ppm CO, confirming safe and efficient burner operation within normal parameters.
Performed annual heating maintenance on the gas furnace, including inspection of the blower compartment, wiring, and condensate drain piping. Verified static pressure with a digital manometer and conducted a combustion analysis, recording 9.3% Oâ‚‚ and 6 ppm CO, confirming safe and efficient burner operation within normal parameters.
Grant O.
Grant O. Checked in
Performed annual heating maintenance on the gas furnace, including inspection of the blower compartment, wiring, and condensate drain piping. Verified static pressure with a digital manometer and conducted a combustion analysis, recording 9.3% Oâ‚‚ and 6 ppm CO, confirming safe and efficient burner operation within normal parameters.
Painesville, OH 44077
Performed an on-site evaluation of the hydronic heating system, inspecting the boiler, copper zone piping manifold, and zone valve actuators (labeled Bedroom and Down) for condition and serviceability. Documented tarnished and oxidized piping, dust and debris accumulation on the boiler, and disorganized low-voltage zone wiring loosely secured with zip ties, with corrosion noted at several pipe joints. Photographed all findings to support a repair or replacement recommendation.
Performed an on-site evaluation of the hydronic heating system, inspecting the boiler, copper zone piping manifold, and zone valve actuators (labeled Bedroom and Down) for condition and serviceability. Documented tarnished and oxidized piping, dust and debris accumulation on the boiler, and disorganized low-voltage zone wiring loosely secured with zip ties, with corrosion noted at several pipe joints. Photographed all findings to support a repair or replacement recommendation.
Bruno D.
Bruno D. Checked in
Performed an on-site evaluation of the hydronic heating system, inspecting the boiler, copper zone piping manifold, and zone valve actuators (labeled Bedroom and Down) for condition and serviceability. Documented tarnished and oxidized piping, dust and debris accumulation on the boiler, and disorganized low-voltage zone wiring loosely secured with zip ties, with corrosion noted at several pipe joints. Photographed all findings to support a repair or replacement recommendation.
Painesville, OH 44077
Performed a heating tune-up, inspecting the furnace and its ignition system. The flame sensor was found with heavy rust and corrosion on its terminal, indicating deterioration that can cause unreliable flame detection and should be cleaned or replaced. Also inspected the return air filter, which was dusty and discolored and had been secured with duct tape, and checked airflow and operation with diagnostic instruments to verify proper system performance.
Performed a heating tune-up, inspecting the furnace and its ignition system. The flame sensor was found with heavy rust and corrosion on its terminal, indicating deterioration that can cause unreliable flame detection and should be cleaned or replaced. Also inspected the return air filter, which was dusty and discolored and had been secured with duct tape, and checked airflow and operation with diagnostic instruments to verify proper system performance.
Jeff M.
Jeff M. Checked in
Performed a heating tune-up, inspecting the furnace and its ignition system. The flame sensor was found with heavy rust and corrosion on its terminal, indicating deterioration that can cause unreliable flame detection and should be cleaned or replaced. Also inspected the return air filter, which was dusty and discolored and had been secured with duct tape, and checked airflow and operation with diagnostic instruments to verify proper system performance.
Painesville, OH 44077
Replaced the air separator cap and float on the Spirovent 1-1/4" air separator and bled air from the hydronic heating lines. Started up the boiler and verified proper operation, with system pressure holding steady at approximately 10–12 psi and no leaks observed at the separator or surrounding piping.
Replaced the air separator cap and float on the Spirovent 1-1/4" air separator and bled air from the hydronic heating lines. Started up the boiler and verified proper operation, with system pressure holding steady at approximately 10–12 psi and no leaks observed at the separator or surrounding piping.
Jeremy F.
Jeremy F. Checked in
Replaced the air separator cap and float on the Spirovent 1-1/4" air separator and bled air from the hydronic heating lines. Started up the boiler and verified proper operation, with system pressure holding steady at approximately 10–12 psi and no leaks observed at the separator or surrounding piping.
Painesville, OH 44077
Replaced the non-responsive brass pressure reducing valve that failed to adjust downstream water pressure when the adjustment screw was turned. Installed the new PRV at the main supply line between the water meter and PEX distribution, set it to the proper regulated pressure, and verified correct gauge readings with no leaks at the connections.
Replaced the non-responsive brass pressure reducing valve that failed to adjust downstream water pressure when the adjustment screw was turned. Installed the new PRV at the main supply line between the water meter and PEX distribution, set it to the proper regulated pressure, and verified correct gauge readings with no leaks at the connections.
Homer J.
Homer J. Checked in
Replaced the non-responsive brass pressure reducing valve that failed to adjust downstream water pressure when the adjustment screw was turned. Installed the new PRV at the main supply line between the water meter and PEX distribution, set it to the proper regulated pressure, and verified correct gauge readings with no leaks at the connections.
Painesville, OH 44077
Performed seasonal furnace tune-up, including measurement of gas manifold pressure with a dual-port manometer (3.54 in. w.c.) and a flue gas combustion analysis, which recorded 13.3% O2 and 17 ppm CO, within acceptable operating limits. Inspected the heat exchanger cabinet, venting, and associated piping and wiring, with no visible rust, damage, or other deficiencies noted.
Performed seasonal furnace tune-up, including measurement of gas manifold pressure with a dual-port manometer (3.54 in. w.c.) and a flue gas combustion analysis, which recorded 13.3% O2 and 17 ppm CO, within acceptable operating limits. Inspected the heat exchanger cabinet, venting, and associated piping and wiring, with no visible rust, damage, or other deficiencies noted.
Grant O.
Grant O. Checked in
Performed seasonal furnace tune-up, including measurement of gas manifold pressure with a dual-port manometer (3.54 in. w.c.) and a flue gas combustion analysis, which recorded 13.3% O2 and 17 ppm CO, within acceptable operating limits. Inspected the heat exchanger cabinet, venting, and associated piping and wiring, with no visible rust, damage, or other deficiencies noted.
Painesville, OH 44077
Performed annual heating preventative maintenance on the furnace, including a combustion analysis and component testing. Recorded a temperature rise of 53°F, static pressure of 0.79" w.c., and flame sense of 2.6 µA, with the hot surface igniter measuring approximately 48–52 Ω, all within normal operating ranges. Combustion readings showed CO at 5 ppm, O2 at 4.1%, CO2 at 6.2%, and steady-state efficiency of 94.2%, confirming safe and efficient operation.
Performed annual heating preventative maintenance on the furnace, including a combustion analysis and component testing. Recorded a temperature rise of 53°F, static pressure of 0.79" w.c., and flame sense of 2.6 µA, with the hot surface igniter measuring approximately 48–52 Ω, all within normal operating ranges. Combustion readings showed CO at 5 ppm, O2 at 4.1%, CO2 at 6.2%, and steady-state efficiency of 94.2%, confirming safe and efficient operation.
Jeff M.
Jeff M. Checked in
Performed annual heating preventative maintenance on the furnace, including a combustion analysis and component testing. Recorded a temperature rise of 53°F, static pressure of 0.79" w.c., and flame sense of 2.6 µA, with the hot surface igniter measuring approximately 48–52 Ω, all within normal operating ranges. Combustion readings showed CO at 5 ppm, O2 at 4.1%, CO2 at 6.2%, and steady-state efficiency of 94.2%, confirming safe and efficient operation.
Painesville, OH 44077
Performed routine tune-up and inspection on a Rudd natural gas furnace (approx. 8 years old); system was operating normally with no reported issues. Conducted combustion analysis with a Testo 310 II, recording 94.4% efficiency, 9.8% O2, 6.28% CO2, 20 ppm CO (38 ppm air-free), and 78.3% excess air, all within acceptable operating parameters. Verified gas manifold pressure with a dual port manometer (approx. 3.5 inWC), confirming proper gas supply and safe, efficient operation.
Performed routine tune-up and inspection on a Rudd natural gas furnace (approx. 8 years old); system was operating normally with no reported issues. Conducted combustion analysis with a Testo 310 II, recording 94.4% efficiency, 9.8% O2, 6.28% CO2, 20 ppm CO (38 ppm air-free), and 78.3% excess air, all within acceptable operating parameters. Verified gas manifold pressure with a dual port manometer (approx. 3.5 inWC), confirming proper gas supply and safe, efficient operation.
Jeff M.
Jeff M. Checked in
Performed routine tune-up and inspection on a Rudd natural gas furnace (approx. 8 years old); system was operating normally with no reported issues. Conducted combustion analysis with a Testo 310 II, recording 94.4% efficiency, 9.8% O2, 6.28% CO2, 20 ppm CO (38 ppm air-free), and 78.3% excess air, all within acceptable operating parameters. Verified gas manifold pressure with a dual port manometer (approx. 3.5 inWC), confirming proper gas supply and safe, efficient operation.
Painesville, OH 44077
Performed a routine plumbing inspection with camera documentation of the bathroom vanity and under-sink cabinet areas. Visually inspected the dual-basin vanity fixtures and the kitchen-style garbage disposal installation, including the drain line, P-trap, flexible discharge hose, and supply lines, and found no visible leaks, corrosion, or damage. Noted that the under-sink cabinet is crowded with stored household items, and recommended clearing the space to allow easier access and early detection of future leaks.
Performed a routine plumbing inspection with camera documentation of the bathroom vanity and under-sink cabinet areas. Visually inspected the dual-basin vanity fixtures and the kitchen-style garbage disposal installation, including the drain line, P-trap, flexible discharge hose, and supply lines, and found no visible leaks, corrosion, or damage. Noted that the under-sink cabinet is crowded with stored household items, and recommended clearing the space to allow easier access and early detection of future leaks.
Sam F.
Sam F. Checked in
Performed a routine plumbing inspection with camera documentation of the bathroom vanity and under-sink cabinet areas. Visually inspected the dual-basin vanity fixtures and the kitchen-style garbage disposal installation, including the drain line, P-trap, flexible discharge hose, and supply lines, and found no visible leaks, corrosion, or damage. Noted that the under-sink cabinet is crowded with stored household items, and recommended clearing the space to allow easier access and early detection of future leaks.
Painesville, OH 44077
Replaced a toilet with a cracked tank by removing the existing unit and installing a new comfort-height (ADA-height) two-piece toilet in a non-Toto brand, per customer preference. Reused the existing braided stainless steel supply line and chrome shut-off valve, which showed no signs of leaks, rust, or corrosion, and verified a secure, level installation with proper flush operation.
Replaced a toilet with a cracked tank by removing the existing unit and installing a new comfort-height (ADA-height) two-piece toilet in a non-Toto brand, per customer preference. Reused the existing braided stainless steel supply line and chrome shut-off valve, which showed no signs of leaks, rust, or corrosion, and verified a secure, level installation with proper flush operation.
Kyle O.
Kyle O. Checked in
Replaced a toilet with a cracked tank by removing the existing unit and installing a new comfort-height (ADA-height) two-piece toilet in a non-Toto brand, per customer preference. Reused the existing braided stainless steel supply line and chrome shut-off valve, which showed no signs of leaks, rust, or corrosion, and verified a secure, level installation with proper flush operation.
Painesville, OH 44077
Excavated a trench along the foundation and replaced the damaged section of 4-inch drain line, installing new pipe on a bed of gravel. Verified proper slope with a level to ensure positive drainage away from the structure. Pipe is ready for backfill and site restoration.
Excavated a trench along the foundation and replaced the damaged section of 4-inch drain line, installing new pipe on a bed of gravel. Verified proper slope with a level to ensure positive drainage away from the structure. Pipe is ready for backfill and site restoration.
Andrew G.
Andrew G. Checked in
Excavated a trench along the foundation and replaced the damaged section of 4-inch drain line, installing new pipe on a bed of gravel. Verified proper slope with a level to ensure positive drainage away from the structure. Pipe is ready for backfill and site restoration.
Painesville, OH 44077
Performed annual heating system maintenance, including a combustion analysis on the natural gas furnace that recorded a 301.6°F stack temperature, 10 ppm CO, 6.45% CO2, and 82.0% efficiency. Verified electrical operation by testing amperage draw at 2.14 A and checking control wiring connections within the unit cabinet, with all readings confirmed within normal operating parameters.
Performed annual heating system maintenance, including a combustion analysis on the natural gas furnace that recorded a 301.6°F stack temperature, 10 ppm CO, 6.45% CO2, and 82.0% efficiency. Verified electrical operation by testing amperage draw at 2.14 A and checking control wiring connections within the unit cabinet, with all readings confirmed within normal operating parameters.
Jeff M.
Jeff M. Checked in
Performed annual heating system maintenance, including a combustion analysis on the natural gas furnace that recorded a 301.6°F stack temperature, 10 ppm CO, 6.45% CO2, and 82.0% efficiency. Verified electrical operation by testing amperage draw at 2.14 A and checking control wiring connections within the unit cabinet, with all readings confirmed within normal operating parameters.
Painesville, OH 44077
Performed annual heating maintenance on a gas-fired furnace, including inspection of the inducer blower assembly, pressure switch, gas valve, vent connections, and low-voltage wiring, with no signs of corrosion, frost, or component damage. Verified system pressure readings with a digital manometer and confirmed the cabinet interior was clean and all connections secure, leaving the unit in proper operating condition.
Performed annual heating maintenance on a gas-fired furnace, including inspection of the inducer blower assembly, pressure switch, gas valve, vent connections, and low-voltage wiring, with no signs of corrosion, frost, or component damage. Verified system pressure readings with a digital manometer and confirmed the cabinet interior was clean and all connections secure, leaving the unit in proper operating condition.
Evan T.
Evan T. Checked in
Performed annual heating maintenance on a gas-fired furnace, including inspection of the inducer blower assembly, pressure switch, gas valve, vent connections, and low-voltage wiring, with no signs of corrosion, frost, or component damage. Verified system pressure readings with a digital manometer and confirmed the cabinet interior was clean and all connections secure, leaving the unit in proper operating condition.
Painesville, OH 44077
Performed a plumbing membership inspection of the 40-gallon tank-style, power-vent gas water heater (not tankless), verifying the vent blower assembly, PVC venting, gas line, gas control valve, expansion tank, and drain pan were intact with no visible leaks, rust, or damage. Also inspected the washing machine supply box, confirming the water hammer arrestors, braided stainless supply hoses, and shutoff valves were in serviceable condition with only minor fitting tarnish and no active leaks observed.
Performed a plumbing membership inspection of the 40-gallon tank-style, power-vent gas water heater (not tankless), verifying the vent blower assembly, PVC venting, gas line, gas control valve, expansion tank, and drain pan were intact with no visible leaks, rust, or damage. Also inspected the washing machine supply box, confirming the water hammer arrestors, braided stainless supply hoses, and shutoff valves were in serviceable condition with only minor fitting tarnish and no active leaks observed.
Sam F.
Sam F. Checked in
Performed a plumbing membership inspection of the 40-gallon tank-style, power-vent gas water heater (not tankless), verifying the vent blower assembly, PVC venting, gas line, gas control valve, expansion tank, and drain pan were intact with no visible leaks, rust, or damage. Also inspected the washing machine supply box, confirming the water hammer arrestors, braided stainless supply hoses, and shutoff valves were in serviceable condition with only minor fitting tarnish and no active leaks observed.
Painesville, OH 44077
Responded to a callback for a newly installed furnace producing a constant hum. Inspected the furnace electrical cabinet and used a clamp meter to measure amperage draw on the supply wiring, then verified the circuit at the main electrical panel to evaluate the breaker and supply circuit. Electrical readings were checked to isolate the source of the noise and confirm the unit's electrical operation.
Responded to a callback for a newly installed furnace producing a constant hum. Inspected the furnace electrical cabinet and used a clamp meter to measure amperage draw on the supply wiring, then verified the circuit at the main electrical panel to evaluate the breaker and supply circuit. Electrical readings were checked to isolate the source of the noise and confirm the unit's electrical operation.
Joel R.
Joel R. Checked in
Responded to a callback for a newly installed furnace producing a constant hum. Inspected the furnace electrical cabinet and used a clamp meter to measure amperage draw on the supply wiring, then verified the circuit at the main electrical panel to evaluate the breaker and supply circuit. Electrical readings were checked to isolate the source of the noise and confirm the unit's electrical operation.
Painesville, OH 44077
Performed heating system start-up and verified operation in both heating stages. Measured manifold gas pressure with a dual port manometer on W2 (high fire) at 0.31 in. w.c., and conducted combustion analysis with a flue gas analyzer on W1 (low fire), recording stack temperature of 96.1°F, O2 at 13.8%, CO at 8 ppm (23 ppm air-free), CO2 at 4.03%, and combustion efficiency of 92.1%. Readings were within acceptable operating parameters, and the room sensors were taken as requested.
Performed heating system start-up and verified operation in both heating stages. Measured manifold gas pressure with a dual port manometer on W2 (high fire) at 0.31 in. w.c., and conducted combustion analysis with a flue gas analyzer on W1 (low fire), recording stack temperature of 96.1°F, O2 at 13.8%, CO at 8 ppm (23 ppm air-free), CO2 at 4.03%, and combustion efficiency of 92.1%. Readings were within acceptable operating parameters, and the room sensors were taken as requested.
Joel R.
Joel R. Checked in
Performed heating system start-up and verified operation in both heating stages. Measured manifold gas pressure with a dual port manometer on W2 (high fire) at 0.31 in. w.c., and conducted combustion analysis with a flue gas analyzer on W1 (low fire), recording stack temperature of 96.1°F, O2 at 13.8%, CO at 8 ppm (23 ppm air-free), CO2 at 4.03%, and combustion efficiency of 92.1%. Readings were within acceptable operating parameters, and the room sensors were taken as requested.
Painesville, OH 44077
Responded to a main sewer line blockage causing sewage backup at the basement utility room drain, with the toilet and shower also affected and a sewer gas odor present. Accessed the exterior cleanout, inspected the corroded cleanout fitting, and cleared the main line to restore proper drainage. Confirmed flow at all affected fixtures, and standing water in the basement should be extracted and the area sanitized and dried.
Responded to a main sewer line blockage causing sewage backup at the basement utility room drain, with the toilet and shower also affected and a sewer gas odor present. Accessed the exterior cleanout, inspected the corroded cleanout fitting, and cleared the main line to restore proper drainage. Confirmed flow at all affected fixtures, and standing water in the basement should be extracted and the area sanitized and dried.
Homer J.
Homer J. Checked in
Responded to a main sewer line blockage causing sewage backup at the basement utility room drain, with the toilet and shower also affected and a sewer gas odor present. Accessed the exterior cleanout, inspected the corroded cleanout fitting, and cleared the main line to restore proper drainage. Confirmed flow at all affected fixtures, and standing water in the basement should be extracted and the area sanitized and dried.
Painesville, OH 44077
Responded to a "cycle expired call for service" fault displayed on the boiler and inspected the system controls, including the Zone 2 living area zone valve and its actuator motor, along with the White Rodgers thermostat call for heat. Verified zone valve and thermostat operation to confirm proper zone control and system response.
Responded to a "cycle expired call for service" fault displayed on the boiler and inspected the system controls, including the Zone 2 living area zone valve and its actuator motor, along with the White Rodgers thermostat call for heat. Verified zone valve and thermostat operation to confirm proper zone control and system response.
Bruno D.
Bruno D. Checked in
Responded to a "cycle expired call for service" fault displayed on the boiler and inspected the system controls, including the Zone 2 living area zone valve and its actuator motor, along with the White Rodgers thermostat call for heat. Verified zone valve and thermostat operation to confirm proper zone control and system response.
Painesville, OH 44077
What To Expect

Discover The Kobella Difference

Integrity

We provide unmatched repair, replacement, and maintenance services using only the highest quality parts and equipment.

Responsive

When you call us from 8 a.m. to 8 p.m., a technician will arrive that same day to provide the needed services.

Professional

Our knowledgeable technicians do jobs quickly without compromising our commitment to excellence.

Satisfaction Guaranteed

Our team is dedicated to ensuring your 100% satisfaction with every service we perform.

Trusted & Recommended

Our experts have the expertise, training, and extensive industry experience to deliver the highest quality services.

Upfront Pricing

No surprise or hidden fees when you get your invoice. We’re upfront and transparent about pricing from start to finish.

Integrity

We provide unmatched repair, replacement, and maintenance services using only the highest quality parts and equipment.

Responsive

When you call us from 8 a.m. to 8 p.m., a technician will arrive that same day to provide the needed services.

Professional

Our knowledgeable technicians do jobs quickly without compromising our commitment to excellence.

Satisfaction Guaranteed

Our team is dedicated to ensuring your 100% satisfaction with every service we perform.

Trusted & Recommended

Our experts have the expertise, training, and extensive industry experience to deliver the highest quality services.

Upfront Pricing

No surprise or hidden fees when you get your invoice. We’re upfront and transparent about pricing from start to finish.

Review Image
Our Reviews

See What Your Neighbors Are Saying

Had a new combi unit installed to replace an aging boiler and water heater. Couldn’t be happier with the install team! Very professional, knowledgeable, and passionate about their work. They paid attention to the details and executed very well. Extremely happy with the install. Looking forward…

Seth G.

Seth G.

Had a wonderful experience with Kobella. The appointment was set in a very timely fashion. The service technician, Bruno, was professional and courteous. He explained the problem, the different remedies and performed the work quickly and expertly. He cleaned the work area thoroughly and made sure…

Loretta R.

Loretta R.

Our go to call for anything related to plumbing, heating, or cooling. Always available quickly, call ahead prior to arrival and show up on team. Every team member is professional and displays Significant professional knowledge. Have recommended their service to others and feedback has been the…

Mathew R.

Mathew R.

I’m so happy with my new air duct installation! Jon, Greg and the crew were an absolute pleasure to work with from start to finish. Very knowledgeable, hardworking and trustworthy guys who went above and beyond. Super impressed!! Highly recommend Kobella 10/10!!

Carla M.

Carla M.

Kobella did a great job moving my sump drain, replacing the sump pump, and adding a secondary pump with battery backup. They were able to do all of the work the same day as the site survey, and their staff was very friendly and professional. I…

John G.

John G.