It’s always a pleasure to work in Chardon, helping families repair plumbing fixtures or install new ones, take on larger projects such as sewer line repairs, and maintain HVAC systems so they’re running as efficiently as possible.
Community Involvement
- We are proud to be members of the well-established Chardon Chamber of Commerce, and contribute to the support of new business development throughout the community.
- Participating in local Chardon events like the annual Geauga County Maple Festival is a highlight of our year! Look for us during the next parade!
What Our Customers Are Saying
Jim B. in Chardon, OH
Project: Repaired and replaced plumbing and fixtures
“He called before coming, showed up on time and promptly took care of the problem. I cant ask any more than that. Price was reasonable also.”
Leadele R. in Chardon, OH
Project: Repaired a water treatment and purification system
“Diagnosed problem, explained the functioning of my water softener, it’s anticipated life, etc. and fixed the problem instead of trying to sell me a new one prematurely. I respect and appreciate that. He advised me also about future maintenance. I will recommend them and use them again when needed.”
Frequently Asked Questions from Chardon Customers
Q: Is there anything I need to do to get my pipes ready for another Ohio winter? I’ve heard of people’s pipes freezing and bursting, and I’d rather not have a similar mess on my hands.
We’ve prepared this quick checklist to help prepare your home’s plumbing system for winter weather. If you have more specific questions about how to properly insulate pipes, we’d be happy to take your call.
Q: How do I know when my water heater needs to be replaced?
Hot water heaters that have been properly maintained typically last between 8 and 12 years. Check out this article which answers your question more in-depth.
Q: How do I tell if my water is unhealthy? Should I install a water filtration system?
Water filtration systems can do much more than provide clean drinking water. After reading this list of benefits, give us a call to discuss your water needs more thoroughly.
Recent Jobs and Reviews in Chardon, OH
Job Locations and Reviews
Responded to call from Joseph Dugan regarding kitchen sink drainage issue. Upon inspection, found clogged drain system connected to garbage disposal unit. Successfully cleared blockage in the PVC piping network under the sink, restoring proper water flow and functionality to the kitchen drain system.
Responded to lead regarding 1994 Carrier furnace exhibiting high carbon monoxide levels. Conducted full inspection of existing HVAC system including ductwork, vents, and mechanical room components. Presented replacement options to customer due to safety concerns with aging equipment.
Returned to install OEM coil temperature sensor as previously sold by Sam. Upon arrival, observed excessive ice and frost buildup throughout the evaporator coil assembly and refrigerant lines, indicating sensor failure. Removed access panel, disconnected electrical connections, replaced defective temperature sensor, and restored proper system operation.
Responded to no-heat service call for 1995 Carrier furnace that was circulating air but failing to ignite. Performed gas pressure testing using dual port manometer, which revealed pressure readings of 323/-324, indicating significant pressure imbalance preventing proper combustion. Adjusted gas valve to manufacturer specifications, cleaned flame sensor, and verified proper ignition sequence, restoring heat function.
Responded to a gas leak complaint involving a propane tank with odors detectable both outside and inside the residence. Upon inspection, identified the source of the leak and shut off the valve at the tank to prevent further gas discharge. Visual examination of the gas line connections to appliance revealed proper installation of flexible yellow gas line with appropriate shutoff valve, though remediation of the tank leak will require follow-up service.
Responded to callback regarding electrical issues that began after initial installation. Performed airflow testing using anemometer at floor registers, confirming 55 CFM delivery. Accessed American Standard thermostat settings and verified proper configuration of single-stage cooling with two-stage gas/oil heating system. Collected remaining balance from original installation.
Cleared severe clog in kitchen sink drain system. Disassembled P-trap assembly showing mineral buildup and removed accumulated debris. Cleaned components thoroughly and reassembled plumbing to restore proper drainage function.
Completed follow-up installation of complete HVAC system sold by JonDZ. Verified proper leveling of all components to ensure optimal system performance and longevity.
Completed routine membership inspection of State ProLine water heater system. Visually inspected all components including supply/return lines, expansion tank, and electrical connections. All equipment appears to be functioning properly with no leaks or issues detected.
Responded to service call for Katherine Eiselsberg regarding water in basement from humidifier and gas odor concerns. Upon inspection, identified condensate pump malfunction on furnace unit causing water leakage. Performed gas leak detection test, tightened loose gas line fitting to eliminate odor. Replaced faulty condensate pump and confirmed proper drainage system operation.
Performed assessment of 15-17 year old Lochinvar boiler system and associated plumbing components. Documented existing installation configuration including water heater, expansion tank, PEX manifold distribution system, and wall-mounted Generac unit. Comprehensive photos taken of utility room setup for estimate purposes.
Successfully completed the installation of a smart WiFi thermostat as previously sold by Sam. Verified proper wiring connections at both the HVAC control panel and thermostat terminal block, ensuring correct wire placement to terminals including R, O/B, Y, G, and C. Confirmed functionality of the heat pump system and instructed customer on basic operation of the new WiFi-enabled device.
Responded to warranty claim #30631637 for non-functioning, leaking garbage disposal. Inspected the 1/2 HP heavy duty unit mounted under stainless steel kitchen sink. Documented existing condition with detailed photos of sink drain assembly and disposal motor housing for warranty company verification.
Installed ICM voltage monitoring surge protector in heat pump and verified refrigerant charge to address heating performance issues. Leveled outdoor unit, sealed air handler/plenum connection to eliminate whistling, installed register on supply trunk, and covered old lineset hole. Addressed customer thermostat questions.
Responded to no heat complaint for aging Distinction furnace. Inspection revealed extensive corrosion and rust on heat exchanger, indicating critical safety hazard. Condemned unit due to cracked heat exchanger which was allowing combustion gases to mix with supply air. Recommended complete system replacement as repair not economically viable for equipment of this age.
Responded to no-heat call for oil furnace making noise before shutdown. Performed combustion analysis with Testo 310 showing O₂ at 3.9% and CO₂ at 12.78%. Inspected and serviced burner assembly which showed signs of wear. Implemented temporary repair solution to restore heat until permanent replacement can be installed next week.
Returned to complete the previously sold water heater installation and shower repair. Installed new Coline water heater with expansion tank and all necessary copper supply lines and valves per code. Confirmed proper function of the bathtub-shower combination unit, including handheld showerhead mount, water controls, and drainage system.
Diagnosed and addressed water intrusion issue in furnace system. Observed significant weathering and corrosion on exterior components, particularly the copper piping and valve assembly. Documented condition with photos showing deterioration of mint-green mechanical components that require attention to prevent further water damage.
Performed installation of Aprilaire filter upgrade kit as previously sold. Removed existing filter and installed new multi-pleated filtration system with diamond-patterned mesh structure in customer's Trane unit. Successfully completed the upgrade per service agreement, with all necessary materials sourced from inventory.
Diagnosed system that was continuously running in auxiliary heat mode despite moderate outdoor temperatures, causing excessive energy consumption (65W auxiliary heat). Inspected thermostat wiring connections and verified proper heat pump/conventional system configuration. Rewired connections at both the outdoor unit and thermostat terminal blocks to restore proper staging sequence, ensuring the system now operates in standard heat pump mode during appropriate temperature conditions.