It’s always a pleasure to work in Chardon, helping families repair plumbing fixtures or install new ones, take on larger projects such as sewer line repairs, and maintain HVAC systems so they’re running as efficiently as possible.
Community Involvement
- We are proud to be members of the well-established Chardon Chamber of Commerce, and contribute to the support of new business development throughout the community.
- Participating in local Chardon events like the annual Geauga County Maple Festival is a highlight of our year! Look for us during the next parade!
What Our Customers Are Saying
Jim B. in Chardon, OH
Project: Repaired and replaced plumbing and fixtures
“He called before coming, showed up on time and promptly took care of the problem. I cant ask any more than that. Price was reasonable also.”
Leadele R. in Chardon, OH
Project: Repaired a water treatment and purification system
“Diagnosed problem, explained the functioning of my water softener, it’s anticipated life, etc. and fixed the problem instead of trying to sell me a new one prematurely. I respect and appreciate that. He advised me also about future maintenance. I will recommend them and use them again when needed.”
Frequently Asked Questions from Chardon Customers
Q: Is there anything I need to do to get my pipes ready for another Ohio winter? I’ve heard of people’s pipes freezing and bursting, and I’d rather not have a similar mess on my hands.
We’ve prepared this quick checklist to help prepare your home’s plumbing system for winter weather. If you have more specific questions about how to properly insulate pipes, we’d be happy to take your call.
Q: How do I know when my water heater needs to be replaced?
Hot water heaters that have been properly maintained typically last between 8 and 12 years. Check out this article which answers your question more in-depth.
Q: How do I tell if my water is unhealthy? Should I install a water filtration system?
Water filtration systems can do much more than provide clean drinking water. After reading this list of benefits, give us a call to discuss your water needs more thoroughly.
Recent Jobs and Reviews in Chardon, OH
Job Locations and Reviews
Removed and replaced two toilets - installed one standard model and one ADA height unit. Replaced corroded flange on first toilet and installed new wax ring to ensure proper seal. Both units successfully tested for proper function and leak-free operation.
Performed warranty service on heat pump system. Diagnosed evaporator coil with significant frost buildup and ice formation on refrigerant lines. Corrected refrigerant charge and cleaned coil surfaces to restore proper heat exchange functionality and system operation.
Conducted site assessment for potential installation of Aprilaire humidifier system. Inspected existing HVAC infrastructure including blue furnace unit with attached galvanized ductwork and water heater with PVC pipe connections. Documented current setup with photos to develop appropriate humidification solution for the residence.
Responded to customer complaint of sewer smell near washer, which was a recurring issue previously addressed with vent installation. Inspected the plumbing ventilation system in the wall/ceiling area and examined wooden structural elements in the surrounding space to ensure proper air circulation and eliminate odor source.
Completed routine plumbing membership inspection of Lochinvar water heater system. Checked all connections, valves, and piping for proper operation and potential leaks. System appears to be functioning normally with no immediate issues identified.
Responded to service call for suspected thermostat malfunction in mobile home. Visual inspection revealed significant frost buildup on evaporator coils and copper lines, indicating possible refrigerant flow issues. System appears to be an older unit with considerable dust accumulation and normal wear on components.
Returned to property to perform line jetting service sold by Chris AZ. Located and accessed cleanout in snow-covered area. Successfully jetted the drain line to clear blockage and restore proper flow. Confirmed system functioning correctly after service completion.
Responded to service call for 30-40 year old oil boiler that was repeatedly tripping reset button and exhibiting water feed line leak. Inspection revealed significant moisture buildup in pressure gauge and corrosion on internal components. Replaced damaged mounting bracket and addressed leaking water feed line to restore proper system operation.
Performed routine plumbing maintenance visit to assess water treatment system installed in August 2025. Inspected exterior utility connections and kitchen sink fixtures. Evaluated filter replacement schedule for water treatment system and provided replacement filters as needed.
Returned to property to follow up on constant pressure system installation previously sold. Inspected existing basement utility area with well tank, pressure control system, and water treatment equipment. Identified necessary components and confirmed replacement parts have been ordered with expected arrival Monday. Full installation scheduled as an all-day service once parts are received.
Completed warranty replacement of defective circuit board and motor in HVAC system. Removed existing components, installed new control board with proper wire connections to line/neutral terminals, and verified system operation after installation. All components now functioning correctly with proper electrical connections.
Completed warranty replacement of defective control board in HVAC system. Removed existing circuit board, installed new OEM replacement board, reconnected all control wiring harnesses, and verified proper system operation through testing. System now functioning as designed with no operational issues.
Responded to reported kitchen-to-basement water leak. Inspection revealed oxidation on copper pipe connection to InSinkerator disposal unit and water staining around pipe penetrations in cabinet. Serviced connection points and sealed pipe penetrations with foam insulation to prevent further leakage.
Completed installation of American Standard 96% 80K BTU 2-stage furnace with additional cold air return ducting. Final combustion analysis performed with Testo 310 II analyzer showing excellent system efficiency at 95.2% with CO levels within safe parameters (9 ppm) and proper air/fuel ratio (43.8% excess air).
Conducted comprehensive assessment of 28-year-old furnace system in unfinished basement after customer reported temperature control issues, burning odors, and suspected fan motor failure. Visual inspection revealed significant age-related deterioration of the HVAC system, including compromised ductwork and potential safety hazards. Recommended complete system replacement due to unit's advanced age, declining performance, and safety concerns.
Responded to customer complaint regarding water taste and odor issues during routine plumbing membership visit. Inspected toilet installation and water supply connections, noting mineral buildup and sediment accumulation in toilet tank. Cleaned interior tank components and addressed water quality concerns per maintenance protocol.
Completed furnace installation as follow-up to sale by Jon. Performed combustion analysis with Testo 310 II showing efficiency readings of 102.5% with CO2 at 8.2%. Conducted pressure testing using dual port manometer, verifying proper static pressure readings of 0.19"WC. Retrieved space heaters from customer as requested.
Responded to no heat service call on 28-year-old furnace. Diagnostic testing revealed poor combustion efficiency with Testo 310 analyzer showing 92.3% efficiency and 20ppm CO. Performed comprehensive inspection and cleaning, addressing the burning smell reported by homeowner and restoring proper operation to maintain consistent temperature.
Diagnosed and serviced thumping noise from 15-year-old Well-X-Trol pressure tank in residential water treatment system. Confirmed tank is maintaining pressure integrity despite age, as evidenced by hollow sound when tapped, indicating proper air cushion function.
Inspected existing 50-gallon power-vented gas water heater that shows signs of leaking at the top connection point, with visible corrosion and brown staining on tank surface. Customer requested installation of a high-efficiency replacement unit with drain pan and thermal expansion tank. Verified shut-off valve functionality and assessed same-day installation feasibility.