It’s always a pleasure to work in Chardon, helping families repair plumbing fixtures or install new ones, take on larger projects such as sewer line repairs, and maintain HVAC systems so they’re running as efficiently as possible.
Community Involvement
- We are proud to be members of the well-established Chardon Chamber of Commerce, and contribute to the support of new business development throughout the community.
- Participating in local Chardon events like the annual Geauga County Maple Festival is a highlight of our year! Look for us during the next parade!
What Our Customers Are Saying
Jim B. in Chardon, OH
Project: Repaired and replaced plumbing and fixtures
“He called before coming, showed up on time and promptly took care of the problem. I cant ask any more than that. Price was reasonable also.”
Leadele R. in Chardon, OH
Project: Repaired a water treatment and purification system
“Diagnosed problem, explained the functioning of my water softener, it’s anticipated life, etc. and fixed the problem instead of trying to sell me a new one prematurely. I respect and appreciate that. He advised me also about future maintenance. I will recommend them and use them again when needed.”
Frequently Asked Questions from Chardon Customers
Q: Is there anything I need to do to get my pipes ready for another Ohio winter? I’ve heard of people’s pipes freezing and bursting, and I’d rather not have a similar mess on my hands.
We’ve prepared this quick checklist to help prepare your home’s plumbing system for winter weather. If you have more specific questions about how to properly insulate pipes, we’d be happy to take your call.
Q: How do I know when my water heater needs to be replaced?
Hot water heaters that have been properly maintained typically last between 8 and 12 years. Check out this article which answers your question more in-depth.
Q: How do I tell if my water is unhealthy? Should I install a water filtration system?
Water filtration systems can do much more than provide clean drinking water. After reading this list of benefits, give us a call to discuss your water needs more thoroughly.
Recent Jobs and Reviews in Chardon, OH
Job Locations and Reviews
Responded to service call for frozen pipes and no heat. Inspected water meter installation and associated plumbing system showing signs of age and deterioration. Identified and addressed frozen pipe sections, ensuring proper water flow restoration. Confirmed functionality of the system with red shut-off valve and verified no active leaks in the copper and brass plumbing assembly.
Completed replacement of 40-gallon water heater with maintenance kit as previously sold. Additionally performed kitchen sink repairs including installation of new two-handle faucet, disposal unit, shut-off valves, supply hoses, and tubular drain components. Verified proper water pressure (55 PSI) and confirmed normal operation of all newly installed fixtures and appliances.
Performed site assessment for customer interested in furnace replacement with premium Lennox model, prioritizing noise reduction. Inspected existing installation, noting corroded pipe junction against brick wall and current HVAC configuration with foil-covered evaporator coil. Discussed high-efficiency, ultra-quiet Lennox options suitable for the basement installation environment.
Diagnosed water accumulation under the furnace air handler. Inspected drainage system and documented condition of filter and drain connection. Recommended maintenance to prevent future water issues.
Diagnosed 25-year-old furnace with faulty inducer motor. Upon inspection, discovered improper lead connection; corrected wiring issue which allowed flame to ignite but system still failed to activate blower motor. Recommended full system replacement due to age and multiple component failures.
Diagnosed hybrid heat pump system that was not properly switching to gas backup heat. Identified wiring issues at the air handler causing the switchover failure. Corrected the control wire connections and verified proper operation in both heating modes. Customer enrolled in regular maintenance program for the heat pump system.
Responded to service call for a furnace failure where customer reported minimal airflow from vents. Upon inspection, identified need for complete furnace replacement. Removed existing unit showing significant corrosion and wear on housing and connections. Installed new furnace system including replacement of thermostat wiring and mounting hardware, ensuring proper leveling and connection of control wires.
Diagnosed 25-year-old furnace with ignition sequence issue where flame ignites but blower motor fails to activate. Inspection of control board revealed corrosion damage on lower components and deteriorating heat exchanger tubes, indicating end-of-life system failure. Recommended replacement due to age and condition of critical components.
Responded to no heat call for Amana furnace. Investigated gas valve assembly and discovered faulty thermocouple connection causing pilot light failure. Replaced thermocouple and verified proper gas flow through the valve. Also inspected and secured loose PVC condensate drain connection with metal clamps to prevent future leakage. System now operating correctly with proper airflow through vents.
Responded to a lead from Sam K regarding no heat issue. Inspected furnace in unfinished basement with exposed joists and plumbing infrastructure. Diagnostic review indicated unit requires replacement; photos documented current installation conditions including nearby electrical panel and water treatment equipment.
Diagnosed and serviced oil furnace that was not producing heat. Inspection revealed electrical issues within the Beckett oil burner assembly requiring wire reconnection and component testing. System was successfully restored to proper operation with heat output confirmed.
Diagnosed persistent heat pump communication issues on Daikin system for customer reporting heating not maintaining temperature. Error history on thermostat displayed multiple "1E - thermostat Heat Pump communication loss" events. Resolved communication failure between thermostat and heat pump unit, restoring proper system operation and temperature control.
Responded to no water call for customer Teera Lunceford. Diagnosed issue with Thoroughbred sensor system (unit #20220129) connected to home's water supply. Inspected pressure gauge readings and restored water service by adjusting valve settings and recalibrating the monitoring system.
Completed furnace installation as follow-up to sale. Performed wiring connections to control board terminals (W, R, G, B, C, Y2, Y1, O) with appropriate color-coded wiring. Conducted combustion analysis using Testo 310, confirming proper operation with O₂ levels at 12.1% and CO at 7 ppm, which is within safe operating parameters.
Returned to replace ECM blower motor as previously diagnosed. Removed defective motor assembly from housing and installed new ECM blower motor. Verified proper wiring connections on circuit board and tested system operation. Customer also enrolled in maintenance plan. Parts were delivered as scheduled and installation was completed within estimated 2-hour timeframe.
Diagnosed and resolved no-heat issue in aging system by identifying faulty control board components. Replaced damaged wiring connections and verified proper operation using Fieldpiece diagnostic tool, with post-repair readings confirming system is now functioning within normal parameters.
Responded to no heat call for 12-15 year old boiler showing no lights and potential condensate drain clogging. Visual inspection confirmed improper drainage issues. Recommended and scheduled comprehensive system flush and preventative maintenance to restore proper operation and prevent future failures.
Completed installation of complete HVAC system (App ID 2601902323) originally sold by Jon and flipped by Sam with KGS approval. System performance verified with temperature readings at multiple points, confirming proper operation with supply temperatures reaching 127°F.
Performed leak detection on a mini-split system after removing compressor per Brad's instructions. Pressure testing revealed readings of 59.0 and 25.4 PSI at different points in the system. Inspected all braze joints for refrigerant leaks as requested.
Performed inspection of existing HVAC system in basement utility room. Unit identified as Lennox model C33-60D-2F-2 refrigerant evaporator/heat pump section. Customer was referred through home warranty program and may be interested in AC replacement options.