It’s always a pleasure to work in Chardon, helping families repair plumbing fixtures or install new ones, take on larger projects such as sewer line repairs, and maintain HVAC systems so they’re running as efficiently as possible.
Community Involvement
- We are proud to be members of the well-established Chardon Chamber of Commerce, and contribute to the support of new business development throughout the community.
- Participating in local Chardon events like the annual Geauga County Maple Festival is a highlight of our year! Look for us during the next parade!
What Our Customers Are Saying
Jim B. in Chardon, OH
Project: Repaired and replaced plumbing and fixtures
“He called before coming, showed up on time and promptly took care of the problem. I cant ask any more than that. Price was reasonable also.”
Leadele R. in Chardon, OH
Project: Repaired a water treatment and purification system
“Diagnosed problem, explained the functioning of my water softener, it’s anticipated life, etc. and fixed the problem instead of trying to sell me a new one prematurely. I respect and appreciate that. He advised me also about future maintenance. I will recommend them and use them again when needed.”
Frequently Asked Questions from Chardon Customers
Q: Is there anything I need to do to get my pipes ready for another Ohio winter? I’ve heard of people’s pipes freezing and bursting, and I’d rather not have a similar mess on my hands.
We’ve prepared this quick checklist to help prepare your home’s plumbing system for winter weather. If you have more specific questions about how to properly insulate pipes, we’d be happy to take your call.
Q: How do I know when my water heater needs to be replaced?
Hot water heaters that have been properly maintained typically last between 8 and 12 years. Check out this article which answers your question more in-depth.
Q: How do I tell if my water is unhealthy? Should I install a water filtration system?
Water filtration systems can do much more than provide clean drinking water. After reading this list of benefits, give us a call to discuss your water needs more thoroughly.
Recent Jobs and Reviews in Chardon, OH
Job Locations and Reviews
Returned to property to follow up on constant pressure system installation previously sold. Inspected existing basement utility area with well tank, pressure control system, and water treatment equipment. Identified necessary components and confirmed replacement parts have been ordered with expected arrival Monday. Full installation scheduled as an all-day service once parts are received.
Completed warranty replacement of defective circuit board and motor in HVAC system. Removed existing components, installed new control board with proper wire connections to line/neutral terminals, and verified system operation after installation. All components now functioning correctly with proper electrical connections.
Completed warranty replacement of defective control board in HVAC system. Removed existing circuit board, installed new OEM replacement board, reconnected all control wiring harnesses, and verified proper system operation through testing. System now functioning as designed with no operational issues.
Responded to reported kitchen-to-basement water leak. Inspection revealed oxidation on copper pipe connection to InSinkerator disposal unit and water staining around pipe penetrations in cabinet. Serviced connection points and sealed pipe penetrations with foam insulation to prevent further leakage.
Completed installation of American Standard 96% 80K BTU 2-stage furnace with additional cold air return ducting. Final combustion analysis performed with Testo 310 II analyzer showing excellent system efficiency at 95.2% with CO levels within safe parameters (9 ppm) and proper air/fuel ratio (43.8% excess air).
Conducted comprehensive assessment of 28-year-old furnace system in unfinished basement after customer reported temperature control issues, burning odors, and suspected fan motor failure. Visual inspection revealed significant age-related deterioration of the HVAC system, including compromised ductwork and potential safety hazards. Recommended complete system replacement due to unit's advanced age, declining performance, and safety concerns.
Responded to customer complaint regarding water taste and odor issues during routine plumbing membership visit. Inspected toilet installation and water supply connections, noting mineral buildup and sediment accumulation in toilet tank. Cleaned interior tank components and addressed water quality concerns per maintenance protocol.
Completed furnace installation as follow-up to sale by Jon. Performed combustion analysis with Testo 310 II showing efficiency readings of 102.5% with CO2 at 8.2%. Conducted pressure testing using dual port manometer, verifying proper static pressure readings of 0.19"WC. Retrieved space heaters from customer as requested.
Responded to no heat service call on 28-year-old furnace. Diagnostic testing revealed poor combustion efficiency with Testo 310 analyzer showing 92.3% efficiency and 20ppm CO. Performed comprehensive inspection and cleaning, addressing the burning smell reported by homeowner and restoring proper operation to maintain consistent temperature.
Diagnosed and serviced thumping noise from 15-year-old Well-X-Trol pressure tank in residential water treatment system. Confirmed tank is maintaining pressure integrity despite age, as evidenced by hollow sound when tapped, indicating proper air cushion function.
Inspected existing 50-gallon power-vented gas water heater that shows signs of leaking at the top connection point, with visible corrosion and brown staining on tank surface. Customer requested installation of a high-efficiency replacement unit with drain pan and thermal expansion tank. Verified shut-off valve functionality and assessed same-day installation feasibility.
Diagnosed wall-mounted natural gas heating system with operational fan failure. Removed and replaced damaged blower motor mounting bracket, restoring proper fan functionality and system heat production. Unit now operating within normal parameters.
Successfully completed the scheduled return service to replace the inducer motor assembly in customer's HVAC system. Installed new inducer motor, tested ignition sequence, and verified proper system operation. Additionally, sold and implemented comprehensive maintenance plan to prevent future issues and extend equipment life.
Diagnosed and adjusted Honeywell relay controlling boiler heat output in basement mechanical area. Recalibrated system to prevent overheating issue in bedroom zone. Verified proper operation after adjustment.
Performed scheduled heating maintenance service on two furnaces and a boiler as part of customer's maintenance membership. Inspected circulation pump assembly, control relays, and associated copper piping. Examined BSM Aire unit, verifying proper wiring connections and operational safety systems.
Returned to complete installation of pressure switch sold by Matt Hdz. Accessed furnace interior, removed defective pressure switch, and installed new OEM replacement. Verified proper electrical connections to control board and tested system operation to confirm switch functions correctly during normal heating cycle.
Completed warranty return service call for TEM840C4S41SRA unit. Performed inspection of electrical panel and control box, examining circuit breakers and wiring connections. Replaced defective warranty parts and verified proper system operation before closing access panels.
Returned to complete warranty repair on HVAC system. Replaced defective coil sensor as authorized under parts warranty previously sold by Jeff. Inspection revealed significant dirt accumulation on evaporator coil and corrosion on copper lines. Verified proper operation of new sensor after installation.
Completed return install of furnace as sold by Greg and flipped by Chris (DGS Approved). Installed and tested system with dual port manometer confirming proper pressure readings of 0.18/0.5. Mounted AprilAire air purification system with appropriate PVC venting and electrical connections.
Responded to service callback for Navien wall-mounted unit experiencing blockage. Inspection revealed improper venting installation causing steam condensation and significant ice formation on exterior eaves. Corrected venting configuration to ensure proper exhaust flow and prevent future condensate freezing issues.